TECO International Co., Ltd Home Online office Sitemap About us Contact us
Chinese
 
Products
How to buy
Services
Distributors
Tenders
Procurements
Careers
 
= TECO


  Capacity
 
  Head
 
 
go

  Name:
 
  Password:
 

  
Main Products Related Products New Products In Stock Products  
Valves Brief Gate Valve Check Valve Bottom Valve


Gate valve


Gate valve is one of most extensive use valves.
Gate valve, it's closing part (flashboard) moves along vertical direction of passage axis, the uses is stopping the medium in pipeline, that is completely start and close. Generally speaking, gate valve can't be used for adjusting the flow, it is suitable for low temperature and pressure as well as high temperature and pressure, the different material gate valve can be used in different medium, but usually it can't be used in the pipeline of transporting slurry etc. medium.

Gate valve has following advantages:
1. low liquid resistance
2. low force moment required for start and close
3. it can be used in rig net pipeline which the medium flows in two directions, that is say no direction limitation of medium flow.
4. lower errosion to seal surface than stop valve when it is working.
5. simple structure, good manufacturing process
luxury hotels in Karpun 6. short structure

Gate valve has different kinds of structure forms, the main distinguish is different structure form of seal parts. The popular types of gate valve are slab gate valve and wedging gate valve, and it can be divided as risefall rod gate valve and revolving rod gate valve according to the valve rod's structure.

The principle of chosing wedge gate valve:
1. The requirement of liquid characteristic: low flow resistance, good flow characteristics, strict requirement for seal.
2. The medium of high temperature, high pressure. Such as high pressure steam, high temperature and high pressure oil products.
3. Low temperature medium. Such as liquid nitrogen, liquid hydrogen, liquid oxygen etc. medium.
4. Low pressure and large caliber, such as water project, sewage treatment project.
5. Position of installation: chose revolving rod gate valve when the installation height is limited, chose risefall rod gate valve when the installation height is unlimited.
6. Wedge gate valve is only for start and close, it can't be used for adjusting or throttling.
7. Wedge gate valve is suitable in the condition of low frequency of start and close.

hotels Granada

Model

Nominal pressure

Nominal Dimension

Main Dimension

Performance

Valve Body

Applied Standard

L

D

D1

Z

Ø

H

Applied Temperature

Applied Medium

Z41H-64

6.4

40

50

65

80

100

125

150

200

250

300

350

240

250

280

320

350

400

450

550

650

750

850

165

175

200

210

250

295

340

405

470

530

595

125

135

160

170

200

240

280

345

400

460

525

4

4

8

8

8

8

8

12

12

16

16

23

23

23

23

25

30

34

34

41

41

41

347

438

473

550

669

772

893

1110

1332

1804

2080

<=425

Oil,Water

Steam

?

GB12234

Z41H-100

10

15

20

25

32

40

50

65

80

100

125

150

200

170

190

210

230

240

250

280

310

3850

400

450

550

105

125

135

150

165

195

220

230

265

310

350

430

75

90

110

110

125

145

170

180

210

250

290

360

4

4

4

4

4

4

8

8

8

8

12

12

14

18

18

23

23

25

25

25

30

34

34

41

248

274

300

345

382

505

545

605

665

700

985

1200

<=425

Oil,Water

Steam

WCB

GB12234

 

Chambre Vilamoura

Model

Nominal pressure

Nominal Dimension

Main Dimension

Performance

Valve Body

Applied Standard

L

D

D1

Z

Ø

H

Applied Temperature

Applied Medium

Z41H-16C

1.6

15

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

500

600

130

150

160

180

240

250

265

280

300

325

350

400

450

500

550

600

700

810

95

105

115

135

145

160

180

195

215

245

280

335

405

460

520

580

705

840

65

75

85

100

110

125

145

160

180

210

245

295

355

410

470

525

650

770

4

4

4

4

4

4

4

8

8

8

8

8

12

12

12

16

16

20

14

14

14

18

18

18

18

18

18

18

23

23

25

25

25

30

34

41

238

288

310

318

355

371

373

430

500

614

650

1075

1275

1740

1775

1930

2070

2887

<=425

Oil,Water

Steam

WCB

GB12234

 

Model

Nominal pressure

Nominal Dimension

Main Dimension

Performance

Valve Body

Applied Standard

L

D

D1

Z

Ø

H

Applied Temperature

Applied Medium

Z41H-40

4.0

50

65

80

100

125

150

200

250

300

350

400

250

280

310

350

400

450

550

650

750

850

950

160

180

195

230

270

300

375

445

510

570

655

125

45

160

190

220

250

320

385

450

510

585

4

8

8

8

8

8

12

12

16

16

16

18

18

18

23

25

25

30

34

34

34

41

438

473

550

669

776

883

1086

1298

1537

1631

2020

<=425

Oil,Water

Steam

Carbon Steel

GB12234

 

Model

Nominal pressure

Nominal Dimension

Main Dimension

Performance

Valve Body

Applied Standard

L

D

D1

Z

Ø

H

Applied Temperature

Applied Medium

?

Z41T-10

1.0

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

180

195

210

230

255

280

330

380

420

450

480

510

540

600

660

160

180

195

215

245

280

335

390

440

500

565

615

670

780

895

125

145

160

180

210

240

295

350

400

460

515

565

620

725

840

4

4

4

8

8

8

8

12

12

12

16

20

20

20

24

18

18

18

18

18

23

23

23

23

23

25

25

25

30

30

289

334

377

433

527

596

772

905

1045

1177

1345

1497

1936

2110

2410

<=200

Water

Steam

HT200

GB122312

 

Model

Nominal pressure

Nominal Dimension

Main Dimension

Performance

Valve Body

Applied Standard

L

D

D1

Z

Ø

H

Applied Temperature

Applied Medium

Z41W-10

1.0

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

180

195

210

230

255

290

330

380

420

450

480

510

540